Laboratory Investigation Mode
1. Coil Current (I)
2. Construction Parameters (N, B, A)
3. Restoring Hairspring Torsion (k)
4. Core, Pole Geometry & Damping Experiments
1. Desired Ammeter Full-Scale Range (Imax)
2. Circuit Line Current (I)
3. Galvanometer Internal Specs
Shunt $r_s = 0.833\text{ m}\Omega$ bypasses $99.998\%$ of circuit current, protecting the delicate coil.
1. Desired Voltmeter Full-Scale Range (Vmax)
2. Test Voltage Input (V)
3. Galvanometer Internal Specs
Series $R = 399.95\text{ k}\Omega$ limits current draw to $< 50\ \mu\text{A}$, avoiding circuit loading errors.
Physics Concepts: Moving Coil Galvanometer (MCG)
- Radial Magnetic Field: Cylindrical concave pole pieces combined with a coaxial soft-iron core ensure magnetic field lines are always parallel to the plane of the coil (normal $\mathbf{m}$ is perpendicular to $\mathbf{B}$, so $\sin\theta = 1$).
- Constant Deflecting Torque: $\tau = NIAB\sin 90^\circ = NIAB$ throughout rotation.
- Restoring Hairspring Torque: Opposed by phosphor-bronze spring: $\tau_{\text{restoring}} = k\phi$.
- Linear Scale Condition: Equating torques gives $\phi = \left(\frac{NAB}{k}\right)I$, producing a strictly linear scale.
- Current Sensitivity: $S_i = \frac{\phi}{I} = \frac{NAB}{k}$ (scale divisions per microampere).
- Voltage Sensitivity: $S_v = \frac{\phi}{V} = \frac{NAB}{k R_g} = \frac{S_i}{R_g}$ (divisions per millivolt).